Fritz-Haber-Institut der Max-Planck-Gesellschaft

FEL

  AC  CP  MP  PC  TH  MPG

The FHI FEL

User experiments

Links

The following posters describing details and specifications of the FHI FEL have been presented at conferences:

  1. 2013: Control System Overview, presented at the 14th International ICALEPCS Conference
  2. 2013: System Overview, presented at the 35th International Free-Electron Laser Conference
  3. 2013: Control System Integration, presented at the 35th International Free-Electron Laser Conference
  4. 2011: Poster, presented at the 2nd International Particle Accelerator Conference

The electron beamline:

Electron pulses are accelerated in two normal conducting linear accelerators. The beamline was designed and constructed by Advanced Energy Systems, Inc.

ParameterUnitTarget
Electron energyMeV15-50
Energy spreadkeV<50
Charge per pulsepC>200
Micropulse lengthpsec1-10
Micropulse repetition rateGHz1
Macropulse lengthµs1-15
Macropulse repetition rateHz20

The undulator:

The undulator is is a permanent magnet, wedged pole undulator with a variable gap from STI Optronics.

TypePlanar hybrid
MaterialNdFeB
Period (mm)40
Length (m)2
Krms0.5 - 1.6

The emitted light:

Macro-pulse energies for narrow bandwidth conditions (< 1% relative full width at half maximum) at various electron energies

The data plotted as a function of the wavelength (logarithmic scale):

The data plotted as a function of the wavelength (linear scale):

EditUploadEditSideBar © FHI